FPS400-24 standard 200 Series power supply provides 24 V dc
OVERVIEW
The Foxboro Evo™ standard 200 Series power
supplies provide 24 V dc to standard 200 Series
baseplates. The Model FPS400-24 is a 400 W power
supply that is agency certified for use in Division 2
and Zone 2 applications. Two different input voltage
Email:18005021035@163.com
Phone:+86 18005021035
Name:BeiLin
Content details
Product introduction:
The FPS400-24 standard 200 Series power supply provides 24 V dc to the standard 200 Series Subsystem
baseplates at 400 W
OVERVIEW
The Foxboro Evo™ standard 200 Series power
supplies provide 24 V dc to standard 200 Series
baseplates. The Model FPS400-24 is a 400 W power
supply that is agency certified for use in Division 2
and Zone 2 applications. Two different input voltage
power supplies are offered as follows:
120/240 V ac or 125 V dc input (P0922YU)
24 V dc input (P0922YC).
These power supplies are the only power supplies
that have been tested and qualified by Foxboro® for
use with 200 Series FBMs.
For sites where a lower-powered and/or smaller sized
solution than the FPS400-24 power supply is
desired, the FPS240-24 and FPS120-24 power
supplies are available. They are discussed in
200 Series Power Supplies – FPS240-24 and
FPS120-24 (PSS 31H-2FPS).
POWER FACTOR CORRECTION CIRCUITRY
The advanced design for ac inputs (P0922YU)
provides an active sinusoidal current profile for near
unity controlled power factor.
CURRENT LIMITING
The power supply operates as a constant voltage
source with maximum load ratings as listed in the
specifications. If load current attempts to exceed
greater than 110% of maximum current at the rated
25°C load, the output voltage begins to decrease
toward zero, thereby limiting the current delivered to
the load. Upon removal of overload, normal operation
resumes.
OVERVOLTAGE SHUTDOWN
Automatic shutdown occurs if operating conditions
cause excessive output voltage. After the occurrence
of an overvoltage shutdown, input power must be
interrupted to re-establish the output. After the cause
of the shutdown has been removed, the shutdown
circuit resets in less than 30 seconds after the
removal of input power.
DIVISION 2, ZONE 2 APPLICATION
The power supplies are UL and UL-C listed (to
UL 1950) as having a Safety Extra Low Voltage
(SELV) and can be used in Division 2 and Zone 2
applications.
POWER FOR EXTERNAL FIELD DEVICES
The actual amount of power required in a standard
200 Series subsystem depends on the number of
Fieldbus Modules (FBMs)/Fieldbus Communication
Modules (FCMs)/Field Control Processors (FCPs)
being powered, the types of termination assemblies
used, and whether internal or external powering is
used for the individual field device(s)
✔✔✔BeiLin
| Mobile/wechat:+86 18005021035
Email contact:18005021035@163.com.
✔✔✔About Chengdu Sunshine Xi He
Chengdu Sunshine Xi He Electric Co., Ltd. specializes in selling the world’s major electrical brand products overseas direct procurement,
genuine inventory, price preferential after-sales warranty, complete models, the same product, not the same price and service.
Large supply of original imported DCS system accessories, PLC system accessories.
Main :ABB, GE Fanuco, Bentl Bentley, Triconex Invensys, Woodward Woodward, Foxboro, Foxboro,
Westinghouse /Emerson, Reliance Ryan, SchneiderModicon, A-B, HIMA dark horse, Motorola MOTOROLA,
Kollmorgen Kollmorgen Bosch/Rexroth/ Bosch Rixon, NI,YOKOGAWA Yokogawa, and other major brands of DCS system accessories,
robot system accessories, large servo system discontinued spare parts.
✔✔✔Our advantage
1.Deep discount
2.Special price, limited time special price
3.Fast delivery and one year warranty!
4.24/7 service and free online quotes
✔✔✔How to ship?
≈For goods that are available, we will place an order upon receipt of payment。
≈We can ship all over the world through SF Express and Federation.The packing is very strong.
If you have any special needs, please let me know
≈You can expect to receive the item approximately 7 days after we send it.
✔✔✔more
FOXBORO | CP30 | FOXBORO | FBM242 |
FOXBORO | CP30B | FOXBORO | FCM10E |
FOXBORO | CP40 | FOXBORO | P0903CW |
FOXBORO | CP40B | FOXBORO | P0914XB |
FOXBORO | CP60 | FOXBORO | P0916AE |
FOXBORO | FBI10E P0972AJ | FOXBORO | P0916AG |
FOXBORO | FBM201 | FOXBORO | P0916DC |
FOXBORO | FBM203 | FOXBORO | P0926JM |
FOXBORO | FBM203 P0914SV | FOXBORO | FBM211 |
FOXBORO | FBM206 | FOXBORO | FBM211 |
FOXBORO | FBM207C | FOXBORO | FBM214 |
FOXBORO | FBM211 | FOXBORO | FBM215 |
FOXBORO | FBM214 | FOXBORO | FBM216B P0927AJ |
FOXBORO | FBM215 | FOXBORO | FBM217 |
FOXBORO | FBM216B P0927AJ | FOXBORO | FBM219 |
FOXBORO | FBM217 | FOXBORO | FBM223 |
FOXBORO | FBM219 | FOXBORO | FBM231 |
FOXBORO | FBM223 | FOXBORO | FBM237 |
FOXBORO | FBM231 | FOXBORO | FBM242 |
FOXBORO | FBM237 | FOXBORO | FCM10E |
FOXBORO | B0123HE | FOXBORO | P0903CW |
FOXBORO | CP30 | FOXBORO | P0914XB |
FOXBORO | CP30B | FOXBORO | P0916AE |
FOXBORO | CP40 | FOXBORO | P0916AG |
FOXBORO | CP40B | FOXBORO | P0916DC |